Rieker manufactures Manual, Digital, and Electronic Inclinometers. A tilt sensor or inclinometer measures tilt, slope or angle of an object in relation to gravity.
Baseline Digital Inclinometer Manual
Contents
Inclinometers Sherborne Sensors' high precision inclinometers are designed to measure horizontal and vertical angular inclination with virtually infinite resolution.
Geokon Inclinometer Manual
Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . 1 The Inclinometer Probe . . . . . . . . . . . . . 2 Control Cable . . . . . . . . . . . . . . . . . . . . . . 4 Taking Readings . . . . . . . . . . . . . . . . . . . . 6 Data Reduction. . . . . . . . . . . . . . . . . . . . . 8 Inspection and Maintenance. . . . . . .12 Digitilt Inclinometer Probe Manual, 11/2011 Introduction Inclinometer System An inclinometer system includes inclinometer casing, an inclinometer probe and control cable, and an inclinometer readout unit. Inclinometer casing is typically installed in a near-vertical borehole that passes through a zone of suspected movement. The bottom of the casing is anchored in stable ground. The inclinometer probe is used to survey the casing and establish its initial position. Ground movement causes the casing to move away from its initial position. The rate, depth, and magnitude of this movement is calculated by comparing data from the initial survey to data from subsequent surveys. This Manual This manual addresses the use and maintenance of the inclinometer probe and control cable. It also provides an overview of taking readings and reducing data. Other manuals cover casing installation, inclinometer readouts, and software for reducing data. Digitilt Inclinometer Probe Manual, 11/2011 1 The Inclinometer Probe Parts of the Probe The inclinometer probe consists of a stainless steel body, a connector for control cable, and two pivoting wheel assemblies. When properly connected to the control cable, the probe is waterproof and has been used deeper than 1000 feet. The wheel assemblies consists of a yoke and two wheels. One of the wheels in each assembly is higher than the other. This wheel is called the “upper wheel” and has special significance, as explained below. Control cable Connector for control cable Upper wheel of upper wheel assembly Upper wheel of lower wheel assembly Measurement Planes The inclinometer probe employs two forcebalanced servo-accelerometers to measure tilt. One accelerometer measures tilt in the plane of the inclinometer wheels. This is the “A”axis. The other accelerometer measures tilt in the plane that is perpendicular to the wheels. This is the “B” axis. The drawing at right shows the probe from the top. When the probe is tilted toward the A0 or B0 direction, readings are positive. When the probe is tilted in the A180 or B180 directions, readings are negative. Positive tilt readings Top Negative tilt readings SE SOR2c c Upper Wheel Probe In a standard inclinometer survey, the probe is drawn from the bottom to the top of the casing two times. In the first pass, the upper wheels of the probe should be inserted into the A0 groove. This ensures that movements are positive values. Always start surveys with upper wheel in A0 groove. Digitilt Inclinometer Probe Manual, 11/2011 Expected Direction of Movement Orientation of the Probe Inclinometer casing is installed so that one set of grooves is aligned with the expected direction of movement. One groove, typically the “downhill” groove should be marked A0. A0 “downhill” groove 2 Handling the Probe The inclinometer probe is a sensitive measuring instrument. Handle it with care. • Transport the probe in its carrying case. If you drive to the site, carry the casing in the passenger compartment, preferrably on a passenger seat. • When you connect control cable to the probe, avoid overtightening the nut, since this will flatten the O-ring and reduce its effectiveness. • Before you lower the probe into the casing, turn the power on. • When you insert the probe into the casing, cup the wheels with your hands to compress the springs and allow smooth insertion. • When you lower the probe into the borehole, do not allow it to strike the bottom. • When you withdraw the probe from the casing, again cup the wheels with your hands to prevent them from snapping out. • When you rotate the probe, keep it upright and perform the rotation smoothly. • The probe is rated for temperatures from -20 to 50 °C (-4 to 122 °F). Avoid using the probe in temperatures outside this range. Caring for the Probe This is an overview. See the last chapter, Inspection and Maintenance, for additional information. Cleaning the Probe: When you finish a survey, wipe moisture off the probe and replace the protective cap. If necessary, rinse the probe in clean water or wash it with a laboratory grade detergent when you return to the office. Cleaning the Connectors: Do not clean connectors with spray lubricants or electri- cal contact cleaners. Solvents in these products will attack the neoprene inside the connector. When it is necessary to clean the connectors, use a cotton swab slightly moistened with alcohol. Be careful to use only a small amount of alcohol. Drying the Probe: When you return to the office, remove protective caps from the control cable, probe, and readout unit. Allow connectors to air-dry thoroughly for a number of hours. Afterwards, replace the caps. Storing the Probe: The probe, control cable, and readout unit should be stored in a dry place. For extended storage, keep the probe in a vertical position. Lubricating the Wheels: Lubricate the wheels regularly. Spray a small amount of lubricant or place a drop of oil on both sides of the wheel bearings. Check that the wheels turn smoothly. O-Ring Care: Periodically clean and lubricate the O-ring on the connector end of the inclinometer probe. Use O-ring lubricant. Digitilt Inclinometer Probe Manual, 11/2011 3 Control Cable Introduction Control cable is used to control the depth of the inclinometer probe. It also conducts power to the probe and returns signals to the readout. • Metric control cables are graduated with yellow marks at 0.5 meter intervals and red marks at 1-meter intervals. There are numeric marks at 5-meter intervals. • English control cables are graduated with yellow markers at 2-foot intervals and red markers at 10-foot intervals. There are numeric labels at every red marker (ten-foot intervals). Depth Control Accurate inclinometer measurements depend on consistent placement of the inclinometer probe. Always align the depth marks on the control cable with the same reference. Aim for placement repeatability of 6 mm (1/4 inch) or better. We recommend using a pulley assembly to assist with depth control. The jam cleat on the pulley assembly holds the cable and the top edge of the chassis provides a convenient reference for cable depth marks. The small pulley assembly is used with 48 mm and 70 mm casing (1.9 and 2.75 inch). The large pulley assembly is used with 70 mm and 85 mm casing (2.75 and 3.34 inch). Using the Pulley Assembly 1. 2. 3. 4. Remove the pulley from the chassis. Clamp the chassis to the top of the casing. Insert the inclinometer probe and control cable. Replace the pulley. Note: The distance between the top edge of the pulley chassis and the top of the casing is one foot. Your data reduction software can automatically adjust for this, so keep your survey procedure simple: use the marks on the cable and the top edge of the pulley chassis for reference. Let the software do any extra work required. Check that operators consistently use the pulley assembly. If the pulley is used for one survey and not for the next, the resulting data sets will not be directly comparable. Sometimes a monument case or a protective pipe makes it impossible to attach the pulley assembly to the casing. In this case, you can make a removable adapter for the pulley assembly. If you use an adapter, be sure to use it consistently. Digitilt Inclinometer Probe Manual, 11/ 2011 4 Cable Tips Connecting Cable: When you connect control cable to the probe, avoid overtight- ening the nut, since this will flatten the O-ring and reduce its effectiveness. Calibrate your Cable: If you have time, “calibrate” your cable, recording the exact position of cable marks. This can be important for long term monitoring projects. Caring for Cable Cleaning the cable: If necessary, rinse the cable in clean water or wash the cable in a laboratory-grade detergent, such as Liquinox.® Do not use solvents to clean the cable. Be sure the protective cap is in place before immersing the end of the cable in water. Do not immerse the Lemo connector. Cleaning Connectors: If it is necessary to clean the connector, use a cotton swab moistened with a small amount of alcohol. Do not use spray lubricants or electric contact cleaners. Solvents contained in such products will attack the neoprene inserts in the connectors. Drying Connectors: When you return to the office, remove protective caps from the control cable, probe, and readout unit. Allow connectors to air-dry well for a number of hours. Storage: Store cable on a cable reel when possible. The reel should have a mini- mum hub diameter of 300 mm (12 inches). If a reel is not available, use the technique below to coil the cable. Coiling Cable 1. Loop cable forward as shown in drawing. 2. Twist cable backwards to make a second loop as shown in drawing. 3. Continue coiling cable, alternating loops as in steps 1 and 2. Digitilt Inclinometer Probe Manual, 11/201 5 Taking Readings Good Practices • Use the same probe and control cable for each survey, if possible. • Use a pulley assembly, if possible. It protects the control cable and provides a good reference. • Use a consistent top reference. The goal is placement repeatability within 5 mm or 1/4 inch. If one technician uses a pulley and another technician does not, probe positioning will be inconsistent, and data will have to be manipulated before it is useful. • Always draw the probe upward to the reading depth. If you accidentally draw the probe above the intended depth, lower the probe down to the previous depth, then draw it back up to the intended depth. This technique ensures the probe will be positioned consistently. • Wait 10 minutes for the probe to adjust to the temperature of the borehole. • Wait for displayed readings to stabilize as much as possible. If the readings do not stabilize, try to record an average reading. Setting Up 1. When you arrive at the site, lay out a plastic sheet or tarp to set the equipment on. You should have the inclinometer probe, the indicator, the control cable, and the pulley assembly. Some people find it is useful to bring a basket or box to hold the control cable and a rag to wipe off the probe and cable after readings have been taken. Unlock and remove the protective cap from the casing. Attach the pulley assembly. Remove protective caps from probe and control cable. Align the connector key with the keyway in the probe. Then insert the connector and tighten the nut to secure the connection. Do not over-tighten the nut, since this will flatten the O-ring and reduce its effectiveness. Turn on the indicator. This energizes the accelerometers, making them less susceptible to shock. Insert the probe into the casing with the upper wheels of both wheel assemblies in the A0 groove. (Cup the wheels with your hands to compress the springs for a smooth insertion). If you are using the pulley assembly, take out the pulley wheel, insert the probe, and then replace the wheel. Lower the probe slowly to the bottom. Do not allow it to strike the bottom. Allow the probe to adjust to the temperature inside the casing. Five or ten minutes is usually sufficient. 2. 3. 4. Position the Probe 1. 2. 3. Digitilt Inclinometer Probe Manual, 11/20 6 Record Data 1. Raise the probe to the starting depth. Wait for the numbers on the readout to stabilize. If you are using the DataMate, press the button to record both the A and B axis readings. If you are using a manual indicator, write down the A-axis reading, then switch to the B-axis and record that reading. Raise the probe to the next depth. Wait for a stable reading, and then record it. Repeat this process until the probe is at the top of the casing. Remove the probe and rotate it 180 degrees, so that the lower wheels of both wheel assemblies are inserted into the A0 groove. When you remove the probe, cup the wheels with your hands to prevent them from snapping outwards. Also, hold the probe upright when rotating it. Lower the probe to the bottom, raise it to the starting depth, and continue the survey. Take readings at each depth until you have reached the top. Remove the probe. At this point, you may want to validate the data set and make any corrections necessary. 2. 3. 4. Leaving the Site Wipe off the probe and cable. Replace end-caps on cable and probe and return the probe to its protective case. Replace the indicator’s protective plugs. Coil the cable. Remove the pulley assembly and replace and lock the protective cap. Wipe off the indicator and recharge its batteries. Transfer the data set to a PC. Oil the probe wheels. If the storage place is dry, remove protective caps from probe, indicator, and control cable to allow all connectors to dry. At the Office Digitilt Inclinometer Probe Manual, 11/20 7 Data Reduction Inclinometer Measurements The inclinometer probe measures tilt, rather than lateral movement. How does tilt provide information about lateral movement? The basic principle involves the sine function, an angle, and the hypotenuse of a right triangle. We are interested in the length of the side opposite the angle θ. side opposite sin θ = --------------------------------hypotenuse side opposite = hypotenuse × sin θ side opposite enus e q Deviation In the drawing at right, the hypotenuse of the right triangle is the measurement interval. The measurement interval is typically 0.5 m with metric-unit inclinometers or 2 feet with English-unit inclinometers. The side opposite the angle of tilt is deviation. It is calculated by multiplying the sine of the angle of tilt by the measurement interval. This calculation translates the angular measurement into a lateral distance and is the first step to calculating lateral movement. Angle of Tilt Cumulative Deviation By summing and plotting the deviation values obtained at each measurement interval, we can see the profile of the casing. The black squares at each measurement interval represent cumulative deviation values that would be plotted to show the profile of the casing. Cumulative Deviation d1 + d2 + d3 θ3 d1 + d2 θ2 d1 θ1 d 1 = L x sinθ1 d 3= L x sinθ3 d 2 = L x sinθ2 d n = L x sinθn Digitilt Inclinometer Probe Manual, 11/20 hypo t L Measurement Interval 8 Displacements Changes in deviation are called displacements, since the change indicates that the casing has moved away from its original position. When displacements are summed and plotted, the result is a high resolution representation of movement. Incremental displacement plot shows movement at each measurement interval. The growing “spike indicates a shear movement. Cumulative displacement plot shows a displacement profile. Displacements are summed from bottom to top. Digitilt Inclinometer Probe Manual, 11/2011 9 Reducing Data Manually Displayed Readings Normally, computer so ware is used to reduce inclinometer data. Here, we show only a simple overview. Slope Indicator’s readouts display “reading units” rather than angles or deviation. Reading units are de ned below: Displayed Reading = sin θ × Instrument Constant Reading English = sin θ × 20,000 Reading Metric = sin θ × 25,000 Combining Readings e standard two-pass survey provides two readings per axis for each interval. e probe is oriented in the “0” direction for the rst reading and in the “180” direction for the second reading. During data reduction, we nd the algebraic di erence of the two readings, and then we divide by 2, since there were two readings. Use of the algebraic di erence lets us preserve the direction of the tilt, as indicated with a positive or negative sign. A0 Reading = 359 A180 Reading = – 339 – ( – 339 ) Algebraic Dierence = 359 ---------------------------------- = 349 ------2 2 Calculating Deviation To calculate lateral deviation, we nd the algebraic di erence of the two readings, divide by 2, divide by the instrument constant, and multiply by the measurement interval. In the example below, the English-unit measurement interval is 24 inches and the English-unit instrument constant is 20,000. Lateral Deviation = Measurement Interval x sin θ 359 – ( – 339 ) = 24 inches × ---------------------------------2 × 20, 000 = 0.4188 inches Find the algebraic di erence of the A0 & 180 readings and divide by 2. Divide reading unit by instrument constant to obtain sine of angle. Calculating Displacement Displacement, the change in lateral deviation, indicates movement of the casing. To calculate displacement, we need two surveys. We subtract the algebraic di erence of the initial reading from the algebraic di erence of the current reading, divide by 2 x the instrument constant, and multiply by the length of the measurement interval. Algebraic Dierence current = 700 Algebraic Dierence initial = 698 Displacement = Measurement Interval × ∆ sin θ 700 – 698 = 24 inches × --------------------------2 × 20, 000 = 0.0012 inches Digitilt Inclinometer Probe Manual, 11/201 10 Calculating Checksums A checksum is the sum of a “0” reading and a “180” reading at the same depth. A0 reading = 359 = 20 A180 reading = -339 Checksum = 359 + (-339) Bias (zero o set) If you hold your inclinometer probe absolutely vertical and check the reading, you will typically see a non-zero value for each axis. e non-zero value is the result of a slight bias in the output of the accelerometers. e bias (or zero o set) may be negative or positive and will change over the life of the probe. is is not normally a matter for concern, because the zero o set is e ectively eliminated by the standard two-pass survey and the data reduction procedure. Below, we show an readings that have a zero o set of 10. During the rst pass the probe measures a tilt of 1 degree. During the second pass the probe measures a tilt of -1 degree, because it has been rotated 180 degrees. See how the o set increases the positive reading and decreases the negative reading, even though the measured angle has not changed. However, when the two readings are combined, as discussed in “Combining Readings” above, the o set is eliminated and the correct value emerges. y (reading) m (sensitivity) b (zero o set) x (degrees) Tilt angle = 1 degree. Theoretical reading unit = 349 Oset = 10 Displayed A0 reading = 359 Displayed A180 reading = -339 Algebraic Dierence = 698 Algebraic Dierence 349 ------- = 2 ( 349 + 10 ) ( -349 + 10 ) ( 359 - (-339) ) ( 20,000 x sin (1) ) Digitilt Inclinometer Probe Manual, 11/2011 11 Inspection & Maintenance Probe Inspection Part Wheel yoke What to check for Side to side movement Remedy Check pivot pin, which looks like screw. If pivot pin has been turned too far, it may spread the wheel yoke. Turn the pivot pin counter-clockwise to see if movement disappears. If movement persists, replace the nylon spacers or the entire wheel assembly. The wheel assembly can be replaced by the user: kit number 50302555. If yoke is dirty, clean it. If problem persists, spring may be broken or weak. Replace spring and roll pins or replace wheel assembly using kit 50302555. Bad bearing. Replace wheel assembly. Lubricate. If movement is still bad, replace wheel assembly. Tighten screws. (Do not tighten pivot pin). Worn keyway may degrade O-ring seal. Learn how to connect cable without “hunting.” Remove corrosion and change practice - allow connector to dry after use. Replace if flattened or split. Bent pins are easily broken when straightened. Replacement of connector requires recuperation of probe (expensive). Change connection practice - no hunting. Wheel yoke Yoke does not return to fully extended position. Side to side movement Does not turn freely Loose screws, wobble in body, loose bumper Wear, corrosion Wheel Wheel Body screws Connector keyways Connector O-ring Connector pins Flattened, split Bent pins Probe Maintenance Moisture Management Wipe off the control cable and probe when you finish the day’s final survey, then wipe off the probe. Do not store wet cloth with the probe. Allow the connector to dry thoroughly: remove connector cap and allow connector to air-dry for a number of hours. Lubricate the wheels. This helps displace moisture. Lubricate the wheels by spraying a small amount of lubricant or placing drops of oil on both sides of the wheel bearings. Lubricate regularly with O-ring lube or silicone based grease. Do not use WD-40 or any other lubricant spray that contains chlorinated solvents. Clean connectors as necessary. Use a slim cotton swab moistened with alcohol. Be careful not to bend pins. Do not use electrical contact cleaners, especially sprays. Solvents in these products will attack the neoprene inside the connectors. When attacked, the neoprene swells and reduces the effectiveness of the Oring seal. Store probe in dry place. Be sure that the box is dry, the wheels are oiled, the connector is dry. If probe is to be stored for an extended period, stand it vertically. Wheels O-Ring Connectors Storage Digitilt Inclinometer Probe Manual, 11/2011 12 Control Cable Inspection Part Cable What to check for Continuity Remedy If you have intermittent failures, perform continuity tests. If a wire fails continuity test, you can check the Lemo connector or return cable for servicing or replacement. Twists indicate poor coiling technique. Change practice: use cable reel, figure-8 coils, or over-under coils. Worn markings: user is dragging cable over the edge of the casing. Change practice - but must keep consistent depths. Kinks: if kinks do not straighten, there is probably internal damage and likelihood of intermittent reading failures. If any deep gouges, water can enter cable. In both cases, bad section of cable must be removed, either by shortening the cable or replacing the cable. Change connection practice - no hunting. Remove corrosion and change practice - allow connector to dry after use. Rubber swells when attacked by WD-40 or contact cleaners. Swelling may prevent good seal and allow water to enter connector. Return for service if sealing is compromised. Perform continuity check first. Then check this connector to eliminate as possible source of intermittent failures. Unscrew bottom nut, being careful not to twist cable. Slide shell off the end of the cable. Slide strain relief collet out of the way and inspect connections. Twist and pull wires gently. Good connections will not break. Repair as necessary. Do not disassemble this connector. Requires about two hours and a pressure test to reassemble. Cable Twists, worn markings, kinks, gouges Connector key Connector rubber insert Wear, corrosion Swelling, poor seal Connector for Indicator (Lemo) Corrosion, bad connection. Connector for Probe Check O-ring Control Cable Maintenance Moisture Management Wipe off the control cable as you draw the probe up on the last run of the day. When you return to the office, remove connector caps and allow connectors to air-dry for a number of hours. When necessary, rinse cable (but not connectors) in clean water or wash the cable in a laboratory-grade detergent, such as Liquinox. Do not use solvents to clean the cable. If it is necessary to clean the connector, use a cotton swab moistened with alcohol. Sockets can be cleaned with a brush. Do not use spray lubricants or electric contact cleaners. Solvents contained in such products will attack the neoprene inserts in the connectors. Improper coiling of any electrical cable twists conductors and can cause reliability problems. There are several ways to control twisting: • Use cable reel with hub diameter of at least 200mm or 8”. • Coil cable in a figure-8. • Coil cable using over-under loops (2-foot diameter loops). Cable Connectors Storing Control Cable Digitilt Inclinometer Probe Manual, 11/2011 13 Control Cable Connectors Below is the wiring diagram for the connectors on the control cable. Testing Connectors are made to mate with each other but not with any other objects. Never insert the probe of your multimeter into a socket. In making the measurements below, simply touch the probe to the top of the socket. Continuity Test: Pin 1 to Pin A, Pin 2 to Pin B, etc, should measure a little less than 1 ohm per 30 m (100 feet). Isolation Test: Pin to pin should measure infinity. Also any pin to the body of the connector should measure infinity. Servicing Use caution when attempting to service either connector. The Lemo connector on the indicator end of the cable is easier to service. When you disassemble the connector, be sure that you do not twist the cables. The heavy connector on the sensor (probe) end of the cable is more difficult to service. We recommend that you send it to the factory unless you are experienced and are willing to spend some time working with it. Digitilt Inclinometer Probe Manual, 11/2011 14
Manual Inclinometer, Buy Various High Quality Manual Inclinometer Products from Global Manual Inclinometer Suppliers and Manual Inclinometer Manufacturers at Alibaba.com.
Casing, refer to the instruction manual for Model 6500 Inclinometer Casing. 6 3. Inclinometer Probe _____ Figure 3 shows the component parts of the inclinometer probe.
Acumar™ DIGITAL INCLINOMETER User’s Manual Version 5.0. The Acumar Digital Inclinometer is the first digital inclinometer to provide easy-to-use, wireless.
A wide standard range of manual and electronic inclinometers, and custom manufacture for OEM customers. Available to buy online, with fast delivery.
The Geokon Model 6150 MEMS In-Place Inclinometer system is designed for long-term monitoring of deformations in structures such as dams, embankments, foundation walls.
Digitilt Inclinometer Probe Manual, 11/2011 3 Handling the Probe The inclinometer probe is a sensitive measuring instrument. Handle it with care.